Model NO.: MCX-R160A
Tube Current: 200mA
Tube Voltage: 40kv-125kv
Mas: 0.4-360mas
Power Supply: 380V 50Hz, Capacity: ≥40kVA
FDA X-ray Developer Fixer: Close-Table Graphic Program Controlled LCD Touchab
Trademark: MeCan
Specification: CE
Origin: Guangzhou
HS Code: 90189070
Conference Headset Image Intensifier Recorder X-Ray Image Intensifiers25kW High frequency Medical X-ray Radiography System
Model:MCX-R160A
Specifications of developer fixer:
Output power | 3kW |
X-ray tube | Fixed anode Max height:≥1750mm, Min height:≤500mm Rotate around horizontal axis 180° Rotate around vertical axis ±90° |
Rectifier method | Full-wave rectifier |
Tube voltage | 40~90kV 9steps |
Tube current | 50~90kV 15mA 50~90kV 30mA 40~80kV 50mA |
Photography time | 50~90kV 15mAÂ Â 0.1~6.3s 50~90kV 30mAÂ Â 0.1~6.3s 40~80kV 50mAÂ Â 0.1~1.5s |
Power supply | 220V±10% 50Hz Inner resistance≤1.0Ω |
Operation methods | Wire control/wireless control (10m) |
Features of x-ray developer fixer:
1. Using ergonomic design, the structure is of compact appearance, convenient operation.
2. It adopts high pressure-resistant electrical tube with enough kV and mA, so the definition and contrast of the machine are good.
3. With combined X-ray generator, the tube and rocker can move up and down freely. So the patient can take photography in a wider range of direction.
4. Because of symmetrical adjustable beam limiting device with light source, the x-ray beam can be adjusted according to demands.
5. X-ray generator is matched with protective stereotype inside, and 10 meters wireless remote control exposure is adopted, so it causes less hurt to the operators and environment.
6. The current has three gears (15mA, 30mA, 50mA), different current can be selected according to different photography requirements, thus using range of machine is wider.
7. Anti-electric shock, anti scattering and full-wave rectifier
8. The electric performance is stable and reliable. Multi-protections are adopted to prevent over-voltage, over-current and output overload etc., so it's safer.
9. Telescopic vertical rotating angle is larger than 60°.
Usage of FDA x-ray developer fixer:
The machine is mobile X-ray radiography medical diagnostic equipment. It can be used in wards, operation rooms and emergency rooms etc., and it can satisfy the radiography requirements of human body such as head, chest and limbs.