10600nm Gold Standard Laser Fractional CO2 Laser Beauty Machine

Model NO.: SM-DZ1
Medical Devices Reg./Record No.: No
Function: Skin Rejuvenation, Scar Removal, Virginal Tighten
Function2: Eleminate Vaginal Dryness Removal
Function3: Striae of Pregnancy Removal
Trademark: SUME
Transport Package: Aluminum Alloy Case/Carton Case/Wooden Case
Specification: 121*42*44cm
Origin: Guangdong China
10600nm Gold Standard Laser Fractional CO2 Laser Beauty Machine
1.Principle:
Vaginal tightening laser is the use of water uptake 10600nm gold standard laser,using a three-dimensional lattice technology and 360-degree circular emission perfect combination of technology, to produce 50-70 degrees Celsius in a controlled depth of the vaginal mucosa, stimulate lamina propria and myometrium newborn fibroblasts, and damaged collagen fibers, elastic fibers, such as restructuring, so as to achieve vaginal wall thickening and tightening of the vagina so that firmness, sensitivity enhancement, vagina tight as ever.
Vaginal tightening laser does not produce skin burns due to high temperature, each capable of Homogeneous heat, acting on a few hundred nanometers thickness Mucosa organization.




2. Specification
10600nm Gold Standard Laser Fractional CO2 Laser Beauty Machine






3.system Parameter adjustment
Fractional model energy parameter reference table
Power(W) 8~15,According to the degree of skin and repair itself the ability to choose, is generally used 9.
Duration(ms) 1.0~2.0,1.0 is generally used, the greater the residence time, the laser acts on the skin longer, whereas shorter.
Repeat(ms) 1.0~2.0,1.0 is generally used, the greater the interval, the faster the laser light, on the contrary, the slower.
Distance(mm) 1.0~2.0,1.0 is generally used, the greater the spacing, the laser effects on the skin point of the more sparsely, on the contrary, more dense.
Scan Generally used sequence.
Overlap(th) 1 is generally used, the laser shot times
Shape The actual shape of the scar selected according to, generally used in the square.
(The above parameters are only limited reference, please be adjusted according to the actual situation)


 
Formal model energy parameter reference table
Single mode Power:(8~15)W,According to adjust the size of the mole the size of the fat particles, generally used 9W.
The residence time: (1.0 ~ 2.5) ms, generally used 1.5ms, the greater the residence time, the laser acts on the skin longer, whereas shorter.
Continuous mode Poser:(6~9)W
Pulse mode Power:(6~12)W,Generally used 8W, according to the cut of meat the size of a mole skin tolerance and other adjustment
(The above parameters are only limited reference, please be adjusted according to the actual situation)



 
Vaginal model energy parameter reference table
Power(W) inside vaginal treatment head:10~20,According to the degree of pain and skin repair their own ability to choose, generally used in 15.
Outside vaginal treatment head:6~9,According to the degree of pain and skin repair their own ability to choose, is generally used 7.
Duration(ms) 1.0~2.0,1.0 is generally used, the greater the residence time, the laser acts on the skin longer, whereas shorter.
Spot size(mm) 1.0~2.0,1.0 is generally used, the greater the spacing, the laser effects on the skin point of the more sparsely, on the contrary, more dense.
Scarn model Generally used in sequence
Shot counter(th) 1 is generally used, the laser shots time
(The above parameters are only limited reference, please be adjusted according to the actual situation)








4. Application
thermal radiation make Mucosa tissue contraction and collagen fibers thereby improving and restructuring vaginal tightening.
1. Shrink vagina: rapid tightening, constriction, lasting firmness.
2. Beautify vagina: dilute pigment, pink labia.
3. Moist vagina: increase secretion, eliminate dryness.
4. Maintenance vagina: deep rejuvenation, prevent aging.
5. To improve sensitivity.
6. Private health, balance PH, improve the internal environment.
10600nm Gold Standard Laser Fractional CO2 Laser Beauty Machine


5.Advantages
1.Without side effects
2.Avoid infection
3.Comfortable and convenient
4.High satisfaction




6.Accessories
10600nm Gold Standard Laser Fractional CO2 Laser Beauty Machine
10600nm Gold Standard Laser Fractional CO2 Laser Beauty Machine






Delivery and Shipping
√ Delivery within 3-5 days off season, 5-7 days in busy season after payment
√ Shipping Way: DHL, UPS, TNT, FedEx etc. in  door to door service  by air 




Our Services
One year warranty: if there any problem happens with machine, we will repair it free of charge
Convenient training:  operation video is available,and we can provide the online face to face education
OEM/ODM services:  logo, language, interface can specially be designed 
10600nm Gold Standard Laser Fractional CO2 Laser Beauty Machine


About us
We are specialized in Beauty and Medical Equipment with professional R&D department, Design &Production and Sales &Service team. Our  machines are sold all over the world, and get good feedback .
                                                                                                   

Medical Led pen light

Diagnostic Pen Light,Pocket Medical Pen Light,Ophthalmic Torch Pen

Wheelchair ramp Stethscoper Co., Ltd. , http://www.youxin-adk.com