25kw 200mA High Frequency X-ray Radiography System

Model NO.: XM160A
Tube Voltage: 40-125kv
Tube Current: 200mA
Main Inverter Frequency: 40kHz
Operation Method: Wire & Wireless Control
Color: White
MOQ: 1
Packing: Standard
Mas: 0.4-360mas
Trademark: Perlong
Transport Package: Carton
Specification: L*W*H
Origin: Jiangsu, China
HS Code: 9022140090
Model NO.: XM160A
Tube Voltage: 40-125kv
Tube Current: 200mA
Main Inverter Frequency: 40kHz
Operation Method: Wire & Wireless Control
Color: White
MOQ: 1
Packing: Standard
Mas: 0.4-360mas
Trademark: Perlong
Transport Package: Carton
Specification: L*W*H
Origin: Jiangsu, China
HS Code: 9022140090
XM160A High Frequency Radiography System 


25kw 200mA High Frequency X-ray Radiography System



 
Technical parameters
 
Component Detail
Power Output 25kW
Inverter Frequency 40kHz
X-ray Tube Rotary anode, Dual-focus, Large focus: 1.3mm*1.3mm,
Small focus: 0.6 mm*0.6mm, Thermal capacity: 900kJ
Rotary Anode Speed 3000rpm
Tube Current 200mA
Tube Voltage 40-125kV
mAs 0.4-360mAs
Table Radiography Grid density: 103L/INCH; Grid ratio: 8:1; Focusing distance: 120cm ;Stationary type:15"×18" (imported)
Bucky Stand Radiography Grid density: 103L/INCH; Grid ratio: 10:1; Focusing distance: 150cm; Stationary type: 18"×18" (imported)
Power Supply 380V 50Hz, Capacity: ≥30kVA
Operation Method Color LCD touch screen graphical control console
20 meters wireless remote exposure control
Configuration Characteristics
Table Size 2000×760mm
Table Height ≤700mm
Transverse Travel of Table ±110mm (Electromagnetic brake)
Longitudinal Travel of Table    ±325mm (Electromagnetic brake)
Cassette Holder Grid Movement ≥560mm (Cassette frame which can linkage with column to take face film; not linkage with the column, to take angle film.)
X-ray Tube Rotation ±90° (Electromagnetic brake)
Floor Stand Rotation 360° (4×90°, Mechanical brake)
Axial Rotation 0-35° (Mechanical brake)
SID 420-1200mm(Electromagnetic brake)
Floor Stand Longitudinal Travel (along table) ≥1350mm (Electromagnetic brake)
Beam Aperture Opening Duration Approx 30s
Film Size 5"×7"-14"×17" (Table radiography)
5"×7"-17"×17" (Bucky stand radiography)
Movement Range of Chest X-ray Frame 560-1625mm



Features

* The latest in compact high-frequency and high-voltage X-ray generator, able to maintain
* LCD touch screen graphical control console can alter radiographic parameters from an adjoining or nonadjacent room  
* Able to apply a variety of radiographic parameters depend upon the physical characteristics of the patient, such as multi-site, multi-position, multi-body shape, adult, pediatric and many more. The user may modify, add and save any parameters for operational convenience
* Counterbalanced X-ray generator can isometrically move and readjust around generator itself, central beam and support stand. This allows for virtually unlimited projection radiographic possibilities for patient placement such as a stretcher
* Provided Bucky stand for radiographic imaging of; head, chest, belly, pelvic cavity, backbone and extremities  
* The latest in compact high-frequency and high-voltage X-ray generator, able to maintain superior image quality at minimal radiation dosage, ensures better patient protection
* Adoption of kV & Max numeric closed loop control technology, enforces real-time microprocessor control, allows for much more accurate and replicable radiation doses accuracy and repeatability of the output dose.
* Features numerous automatic systematic safeguards and fault detection function, contributes to a safer and more reliable user operating experience
* Radiographic table includes electromagnetic braking and is moveable in any cardinal direction, guarantees the accurate and simple placement of patients


 
 


25kw 200mA High Frequency X-ray Radiography System
  
XM160A High Frequency Radiography System 


25kw 200mA High Frequency X-ray Radiography System



 
Technical parameters
 
Component Detail
Power Output 25kW
Inverter Frequency 40kHz
X-ray Tube Rotary anode, Dual-focus, Large focus: 1.3mm*1.3mm,
Small focus: 0.6 mm*0.6mm, Thermal capacity: 900kJ
Rotary Anode Speed 3000rpm
Tube Current 200mA
Tube Voltage 40-125kV
mAs 0.4-360mAs
Table Radiography Grid density: 103L/INCH; Grid ratio: 8:1; Focusing distance: 120cm ;Stationary type:15"×18" (imported)
Bucky Stand Radiography Grid density: 103L/INCH; Grid ratio: 10:1; Focusing distance: 150cm; Stationary type: 18"×18" (imported)
Power Supply 380V 50Hz, Capacity: ≥30kVA
Operation Method Color LCD touch screen graphical control console
20 meters wireless remote exposure control
Configuration Characteristics
Table Size 2000×760mm
Table Height ≤700mm
Transverse Travel of Table ±110mm (Electromagnetic brake)
Longitudinal Travel of Table    ±325mm (Electromagnetic brake)
Cassette Holder Grid Movement ≥560mm (Cassette frame which can linkage with column to take face film; not linkage with the column, to take angle film.)
X-ray Tube Rotation ±90° (Electromagnetic brake)
Floor Stand Rotation 360° (4×90°, Mechanical brake)
Axial Rotation 0-35° (Mechanical brake)
SID 420-1200mm(Electromagnetic brake)
Floor Stand Longitudinal Travel (along table) ≥1350mm (Electromagnetic brake)
Beam Aperture Opening Duration Approx 30s
Film Size 5"×7"-14"×17" (Table radiography)
5"×7"-17"×17" (Bucky stand radiography)
Movement Range of Chest X-ray Frame 560-1625mm



Features

* The latest in compact high-frequency and high-voltage X-ray generator, able to maintain
* LCD touch screen graphical control console can alter radiographic parameters from an adjoining or nonadjacent room  
* Able to apply a variety of radiographic parameters depend upon the physical characteristics of the patient, such as multi-site, multi-position, multi-body shape, adult, pediatric and many more. The user may modify, add and save any parameters for operational convenience
* Counterbalanced X-ray generator can isometrically move and readjust around generator itself, central beam and support stand. This allows for virtually unlimited projection radiographic possibilities for patient placement such as a stretcher
* Provided Bucky stand for radiographic imaging of; head, chest, belly, pelvic cavity, backbone and extremities  
* The latest in compact high-frequency and high-voltage X-ray generator, able to maintain superior image quality at minimal radiation dosage, ensures better patient protection
* Adoption of kV & Max numeric closed loop control technology, enforces real-time microprocessor control, allows for much more accurate and replicable radiation doses accuracy and repeatability of the output dose.
* Features numerous automatic systematic safeguards and fault detection function, contributes to a safer and more reliable user operating experience
* Radiographic table includes electromagnetic braking and is moveable in any cardinal direction, guarantees the accurate and simple placement of patients


 
 


25kw 200mA High Frequency X-ray Radiography System
  

Safety Railing

Safety Railing,Protective Railings,Protective Railing,Isolation Railings

Xuzhou Guifeng Metal Technology Co., Ltd , https://www.guifengmetal.com