Details of BX51 Research Cell Biomicroscope

Excellent optical performance, flexible scalability, from clinical to scientific applications

Arm separation for improved system performance
The BX51 uses a completely new structure, that is, the transmitted light arm is separated from the microscope body, which gives the user greater freedom to configure the system according to their choice.

Observe from 1.25X to 100X without changing the condenser ☆
The seven-hole objective lens transducer U-D7RE can be mounted with seven objective lenses. When viewed continuously from 1.25X to 100X, this objective converter can be used in combination with the U-SC3 pendulum condenser (also compatible with the BX41).
☆ When using a 1.25X objective lens, use ultra-low magnification condenser U-ULC-2.

Up to 4 color filters can be built in
The BX51 is equipped with three color filters (ND6, ND25, LBD) on the mirror base, and an optional fourth. The lever on the side of the mirror base can be easily inserted/removed from the color filter.

Fluorescent unit indicator light, easily identifiable in dark rooms <br>Uses a bright, easy-to-recognize self-illuminating label to indicate the fluoroscope assembly, which is easy to see in a dark room. The ability to display three fluorescent component positions simultaneously makes it easy and intuitive to select the next color filter.

The DP70 Microscope Digital Camera and DP-BSW Software <br> captures high-resolution images equivalent to 12.5 megapixels at high speeds, providing clear fluorescence images with high sensitivity and low noise (equivalent to ISO100---1600). A user-friendly GUI (Graphical User Interface) enables fast, easy capture, adjustment and storage of digital images.

New advances in Olympus fluorescence observations <br> Two types of illuminators are available: the highly stable reflected light illuminator BX-UR2 built into the arm and the fluorescent illuminator BX-RFA. Both can be fitted with six fluoroscope components that can be easily converted with a turntable. Efficient illumination enables doubling the brightness of traditional fluorescent images at low magnifications.

Nomaschi DIC observation, image optimization based on sample characteristics <br>BX51/BX41 with different DIC slides in order to get the best image for different samples. Use the following types: U-DICT or U-DICTS for comprehensive high performance; U-DICTHC for high contrast imaging of thin samples, U-DICTHR for high resolution, glare-free imaging of thick samples . An 8-hole universal condenser (optional) can be combined with other optical components for brightfield, darkfield, phase contrast, Nomsky DIC, and simple polarized viewing.

BX41/51 specifications

project

BX41

BX51

Microscope frame

Optical system

UIS2 optical system

Focus

Vertical movement of the stage: 25mm stage travel with coarse adjustment limiter. Coarse adjustment knob can adjust torque

The mounting position of the stage is variable, and the fine adjustment knob is highly sensitive (minimum adjustment distance: 1 micron)

Illuminator

Built-in transmitted light Kohler illuminator

6V30W filter bulb (pre-adjusted)

Light intensity preset button

Built-in transmitted light Kohler illuminator

12V100W halogen bulb (pre-adjusted)

Light intensity preset button

Light intensity LED indicator

Built-in color filters (LBD-IF, ND6, ND25 and an optional slot)

Objective turntable

Exchangeable 5-hole / 6-hole converter

Observation tube

Wide field of view (field of view 22)

Wide field of view binocular viewing tube with an inclination of 30 degrees.

Wide field of view three-eye observation cylinder with an inclination of 30 degrees.

Wide field of view variable angle binocular viewing tube with an inclination of 5 to 35 degrees.

Wide field ergonomics binocular viewing tube, inclination 0 to 25 degrees

Ultra wide field of view (field of view 26.5)

Ultra-wide field of view trinocular observation cylinder, inclination angle of 24 degrees

Stage

Ceramic surface coaxial stage with left or right hand low position drive with swivel and torque adjustment.

Optional rubber cap (also provides obstacles, grooves, coaxial, flat, rotating stage)

Condenser

·Abbe (numerical aperture 1.1) for 4×~100×

· Shake out achromatic (numerical aperture 0.9) for 1.25 ~ 100 × (after shaking out: 1.25 ~ 4 ×)

· Achromatic aspherical difference (numerical aperture 1.4) for 10~100×

· Phase difference, dark field (numerical aperture 1.1), (phase difference: for 4 × ~ 10 ×; dark field: for 10 × ~ 100 × [numerical aperture is less than 0.7])

· Universal (numerical aperture 1.4/9) for 2 × ~ 100 ×, (after shaking: for 2 × ~ 4 ×; when using oil-impregnated top lens: for 20 × ~ 100 ×)

·Dark field drying type (numerical aperture 0.8~0.92) for 10×~100×

·Dark field oil immersion type (numerical aperture 1.20~1.40) for 10×~100×

· Ultra low (numerical aperture 0.16) for 1.25 × ~ 4 ×

Beijing Jingbai Zhuoxian Technology Co., Ltd.
Contact: Qian Xiang      Mobile: 15189913100

QQ E-mail: qyqxhao@qq .com
Address: Room 2081, 2nd Floor, Building 2, No. 50, Building Materials West Road, Haidian District, Beijing

Plant Extract

Shanghai J.Shine Co.,Ltd , https://www.jshinechem.com