Hospital Newborn Baby Infant Radiant Warmer Medical Equipment (SLVBN-100)

Model NO.: SLVBN-100
Type: Infant Radiant Warmer
Power Supply: 110/220V 60/50Hz
Mattress Size: 67cm X 54cm
Distance From Heater to Mattress: 90cm
Power Input: 1000va
Package: Each Unit Is Packed One Plywood Case
Package Size: 118*90*87cm
N.W: 75kg
G.W: 100kg
Atmospheric Pressure: 500-1060hpa
Timer Range: 0-99h 59min
Trademark: Shileva
Transport Package: Wooden Case
Specification: 2120*900*450-750mm
Origin: China
HS Code: 9402900000
Model NO.: SLVBN-100
Type: Infant Radiant Warmer
Power Supply: 110/220V 60/50Hz
Mattress Size: 67cm X 54cm
Distance From Heater to Mattress: 90cm
Power Input: 1000va
Package: Each Unit Is Packed One Plywood Case
Package Size: 118*90*87cm
N.W: 75kg
G.W: 100kg
Atmospheric Pressure: 500-1060hpa
Timer Range: 0-99h 59min
Trademark: Shileva
Transport Package: Wooden Case
Specification: 2120*900*450-750mm
Origin: China
HS Code: 9402900000
Product name:
Hospital Newborn Baby Infant Radiant Warmer Medical Equipment (SLVBN-100)

Brief introduction:
1. Microprocessor based servo controlled temperature system.
2. The microprocessor-controlled unit allows for three settings: Pre-warm, manual or automatic.
3. Alarm functions for safety includes:
Power failure, temperature deviation,
Temperature sensor failure, over temperature.
4. APGAR timer to record therapy time
5. Convenient X-ray cassette under infant bed
6. Heater head can be adjusted + 90º Horizontally
7. Tilt angle of infant bed is adjustable
8. Halogen Observe light angle is adjustable
9. Transparent protector folded
10. Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source, the heating is quick and life-span
Is long
11. Alarms are audible and visual
12. A second thermal cut-out function for more safety
13. Skin temperature sensor failure protect function avoid over temperature
14. Temperature deviation can be amended in front panel directly

Standard configuration
Main body (including the radiant source, control system, infant bed, bracket), X-ray cassette, Observe light, I. V. Pole, skin
Temperature sensor, tray, mattress, transparent protector, castors.
Optional parts: Drawer, RS-232(485) connector

Technical data:
1. Power supply: 110/220V 60/50Hz
2. Power input: ≤ 1200VA
3. Operating condition
An ambient Temperature: 18° C-30° C
An ambient Relative Humidity: 30%--75%RH
Atmospheric Pressure: 700~1060 hPa
An ambient Air Velocity <0.3m/s
4. Temperature control: 32° C~38° C
5. Temperature control accuracy: ≤ 0.5° C
6. Mattress temperature uniformity: <2° C
7. Skin temperature sensor accuracy: + 0.3° C
8. Warm-up time: ≤ 30min
9. Infant bed tilt angle: + 10°
10. APGAR timer range: ≤ 24h
11. Heater head horizontal: ± 90°
12. Mattress size: 67CM X 54CM
13. Distance from heater to mattress: 90CM

Transport and storage
Environment Temperature: -40° C~ +55° C
Environment Relative Humidity: ≤ 95%
Atmospheric Pressure: 500~1060hPa

Package:

PackageEach unit is packed one case
Size120CMX 70CM X 96CM
Gross weight≤ 90KG

  Product name:
Hospital Newborn Baby Infant Radiant Warmer Medical Equipment (SLVBN-100)

Brief introduction:
1. Microprocessor based servo controlled temperature system.
2. The microprocessor-controlled unit allows for three settings: Pre-warm, manual or automatic.
3. Alarm functions for safety includes:
Power failure, temperature deviation,
Temperature sensor failure, over temperature.
4. APGAR timer to record therapy time
5. Convenient X-ray cassette under infant bed
6. Heater head can be adjusted + 90º Horizontally
7. Tilt angle of infant bed is adjustable
8. Halogen Observe light angle is adjustable
9. Transparent protector folded
10. Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source, the heating is quick and life-span
Is long
11. Alarms are audible and visual
12. A second thermal cut-out function for more safety
13. Skin temperature sensor failure protect function avoid over temperature
14. Temperature deviation can be amended in front panel directly

Standard configuration
Main body (including the radiant source, control system, infant bed, bracket), X-ray cassette, Observe light, I. V. Pole, skin
Temperature sensor, tray, mattress, transparent protector, castors.
Optional parts: Drawer, RS-232(485) connector

Technical data:
1. Power supply: 110/220V 60/50Hz
2. Power input: ≤ 1200VA
3. Operating condition
An ambient Temperature: 18° C-30° C
An ambient Relative Humidity: 30%--75%RH
Atmospheric Pressure: 700~1060 hPa
An ambient Air Velocity <0.3m/s
4. Temperature control: 32° C~38° C
5. Temperature control accuracy: ≤ 0.5° C
6. Mattress temperature uniformity: <2° C
7. Skin temperature sensor accuracy: + 0.3° C
8. Warm-up time: ≤ 30min
9. Infant bed tilt angle: + 10°
10. APGAR timer range: ≤ 24h
11. Heater head horizontal: ± 90°
12. Mattress size: 67CM X 54CM
13. Distance from heater to mattress: 90CM

Transport and storage
Environment Temperature: -40° C~ +55° C
Environment Relative Humidity: ≤ 95%
Atmospheric Pressure: 500~1060hPa

Package:

PackageEach unit is packed one case
Size120CMX 70CM X 96CM
Gross weight≤ 90KG

 

Black Wolfberry Large Grains

Black Ningxia Wolfberry Large Grains,Black Ningxia Goji Berry Large Grains,Ningxia Large Black Goji Berry,Large Ningxia Black Goji Berry Tea

NINGXIA STARLIGHT FOOD TRADE CO.,LTD , http://www.starlightfood.com