Release date: 2016-09-02
 Abdominal braces are widely used to increase the stability of the spine. But how does the application of abdominal braces affect the execution of exercise? There is no relevant research on this issue. Because landing is a common task in the exercise process, it is very important to clearly determine how the abdominal braces will affect the completion of the landing task.
In order to quantitatively determine the effects of abdominal braces on the kinematics of the landing process (the angles of flexion peaks of the ankle, knee, hip and local lumbar spine) and the peak of the vertical reaction force, Campbell et al. from Curtin University of Australia designed the relevant research and The findings were published in the April 2016 issue of J Orthop Sports Phys Ther.
The investigators included 16 healthy adults, 7 of whom were women and 9 were men. In the process of the subject completing the landing task, the researchers applied three-dimensional motion analysis, electromyography and baroreceptor platform, and the completion of the landing task was performed twice, one subject needs to wear the abdominal brace, and the other time does not need to wear. .
The abdominal brace worn by the subject provides real-time EMG feedback to the internal oblique muscle. The researchers also quantitatively analyzed the kinematic parameters of the lower extremities and lumbar vertebrae, the peak anti-force, the normalized electromyogram of the left and right oblique internal oblique muscles and the lumbar multi-fissure muscle.
Vertical reaction force, left and right abdominal oblique muscle myoelectric activity changes in three stages of landing (wearing / not wearing brace)
In the process of landing, if the abdominal brace is worn, the knee and hip joint buckling can be significantly reduced, and the vertical reaction force can be increased. However, the wearing of the abdominal brace does not have a significant effect on the electromyogram of the lumbar multi-fissure muscle or the kinematic parameters of the lumbar spine.
The results of this study indicate that the application of abdominal abutments can reduce the impact of landing during landing, which can reduce the risk of lower limb and lumbar injury during landing.
Source: Lilac Garden
SE-12B Digital Three Channel Color Touch Screen ECG Machine(electrocardiograph)
Features
- The system is designed with a high-resolution thermal printer featuring 8dot/mm
vertical resolution and 40dot/mm horizontal resolution(at 25mm/s) speed and filter as
well as related marks.
- Simultaneously 12 lead signal acquisitions.
- Digital filter to prevent baseline drift and automatic positioning of the baseline provide
accurate ECG trace.
- Able to detect and alarm on electrode disconnection.
- LED indicator and LCD display show operation status of the unit.
- Isolated input circuit guarantees safety standard in compliance to Class I type CF.
- AC/Rechargeable battery supports continuous operation when AC power supply is not
available. For the battery operation, the system is equipped with a battery charger and
a system for battery capacity management and protection.
- Compact size.
Specifications
Lead: Standard or Cabrera 12 leads,Simultaneously 12 leads acquisition
Sampling rate: 1000Hz(1ms)
Frequency Response: 0.05 ~ 150Hz
Time Constant: ≥3.2s
CMRR: >100dB
Input Circuit: <0.1 µA
Noise Level: ≤ 8 µVp∽p
Polarization Voltage: ±500mV
Sensitivity valve: 20 µV
Calibration Voltage: 1mV ±0%
Filter: AC: 50Hz-20dB(or 60Hz); EMG
filter:25-35-45Hz-3dB;
Drift filter: 0.5Hz -3dB
Sensitivity: 1.25, 2.5, 5, 10, 20mm/mV±2%,40 when format setted at 6ch or 3+3ch
Paper Speed: 5, 6.25, 10, 12.5, 25, 50mm/s ±3%
Recording MODE: Thermal array printer 8 dot/mm(Vertical) 40 dot/mm(Horizontal, 25mm/s)
Paper Size: 210mm20m or 216mm20m, thermal roll paper
Ecg Machine,Ecg Machine 12 Channel,Electrocardiograph Machine 6 Channel,Three Channel Ecg Machine