2. The seal is aging or damaged, and the seal is replaced.
There is an abnormality when rotating the handwheel. 1. The handwheel rotates very hard or does not move. The bearing inside the upper end of the squeeze rod lacks lubricating oil or bearing damage, refueling or replacing the bearing.
2. When the handwheel rotates, the extruded rod seat has obvious air leakage, and the internal PTFE seal is damaged and replaced.
Safety valve, leaking at the connection between the pressure gauge and the lid 1. Loosen the tightening nut on the other side of the lid and tighten.
2. The sealing ring at the joint is damaged and replaced.
The pressure gauge shows a pressure of 0.3Mpa, the safety valve does not jump and exhaust 1. The safety valve has a small hole blocking the race, and the cleaning makes it unblocked. 2. The safety valve is damaged and replaced.
The heating is normal, the electric control box shows normal, and the pressure gauge does not indicate the pressure 1. Open the exhaust valve in the lower part of the pressure gauge to see if it is exhausted. If it is not exhausted, there will be a foreign body blocking the small hole, and the cleaning will make it smooth. Exhaust, the pressure gauge is damaged and replaced.
When the lid is opened again, it cannot be fully opened. 1. The pressing plate is not fully rotated to the upper end, and the hand wheel is rotated in the opposite direction until it stops, and then the lid is moved.
2. There is a negative pressure in the decocting mechanism, and the vent valve can be opened after opening the vent valve.
After the power is turned on, the heating indicator light is on, but the temperature does not rise. The heating plate is broken or the electrical line is faulty. After the professional inspection is pressed, the heating indicator is off, the pressure height relay is faulty, and the power switch should be turned off immediately, or unplugged. The power cord plug is pre-repaired by a professional.
Leakage or even the serial valve is not closed, or the valve is worn and leaked and replaced.
The electrical components in the machine leakage device are damp, blow dry after power off, and the electrical components are faulty. Report the repairing and repairing of the pot body to the back and forth. The fixing screw connected to the base and the base is loose. When the screw is tightened, the valve can be opened, and the liquid can not discharge foreign objects. Valve connection pipeline maintenance and troubleshooting, focus on cleaning the Solenoid Valve.
RICTRON Industrial Co., Ltd is a hight-tech OEM/ODM enterprise, we are specialized to produce the products such as fire smoke alarm, carbon monoxiede alarm, gas alarm, water alarm, smoke&co or gas&co combined alarms, and other products of R&D, manufactring and sales since 2008.
We continually strive to maintain our unwavering reputation through our exceptional product quality and customer service. We not only offer a complete line of superior quality products, but also work with our customers to develop new formulas and address the burgeoning market. So, we get so many goods response from our global customers. Welcome your exlusive customization of OEM and ODM, we will grow together and create brillant with you.