phenomenon | Possible Causes | Solution |
The slats are not colored or have no corresponding values | The order of reagents is disordered, or the procedure is wrong. | Repeat the experiment in strict accordance with the experimental instructions |
Different batches of reagents were used | Make sure the reagents are from the same kit | |
The slats are seriously wet | The slats should be sealed, and the desiccant should be replaced in time. | |
low Suck Light degree OD value | Reagent expired, or mixed in different batches | Verify expired reagents and batches |
Incorrect preparation of washing solution, long washing and soaking time | Wash according to the instructions and prepare the lotion properly | |
Incubation time is too short | Strictly calculate the time according to the instructions | |
Reagent contamination | Make sure to pick up different liquids and replace the new tips and containers | |
Reagent temperature is too low | According to the volume of the reagent, the temperature recovery time is extended accordingly to ensure that the reagent is completely warmed up. | |
Use the wrong wavelength reading, or enzyme Standard failure | Ensure 450 nm wavelength reading and check if the microplate reader is malfunctioning | |
The kit is in extreme conditions | Please return the used parts to the refrigerator immediately. Do not put them in an overheated environment for too long. | |
Excessive Background value or absorbance ( OD value) | Poor quality water preparation reagent | Use double distilled or deionized water to prepare reagents |
Improper washing or poor washing of the washing machine | Add 1-2 washes and add at least 250 μL of wash solution per well | |
The microplate reader fails, such as the OD reading is very high and the color is very light | Check the microplate reader with a calibration microplate and check the light source | |
The laboratory temperature is too high and the reaction time is too long | Determine if the operating temperature is appropriate and whether the time is calculated correctly | |
Confused reagents, contaminated or improperly formulated | Ensure that the correct reagents are used, accurately formulated to avoid contamination | |
Inside the board difference Big | Inconsistent time to add standards and samples, etc. | Multi-channel gun loading, the same reagent can not be interrupted during the sample loading |
Improper use of multiple guns | Calibrate multiple guns, check if the nozzles are tight, and ensure consistent liquid absorption | |
The washing system has failed | Check the washing system and keep it running | |
board between difference different Sex Big | The incubation time between the plate and the plate is too different | Independent timing to ensure consistent incubation time |
Inconsistent washing process between plates | Ensure the same number of washings to ensure the washing system is working properly | |
Improper use of a pipette | Check the pipette to make sure you draw the same amount | |
Reagents and samples at different temperatures | Make sure that the reagents and sample liquid in the cartridge are fully warmed up. If the reagent volume is large, it needs to be warmed up for a long time. Can not use warm water bath to return samples | |
Mix different batches of reagents, or the kit expires | Do not mix reagents. Usually , the OD value of 0 standard is less than 0.5, indicating that the reagent quality is degraded. | |
One or Multiple standard data points are outside the curve range | Standards are added in disorder, or placed in the wrong location | Repeat the experiment as required to ensure that the standard is added correctly. |
Standards are contaminated or confused with other standards | Switch to new standards and add standards in order from low to high | |
Inconsistent washing or failure of the washing system | Follow the washing method as always, check the washing system | |
Inconsistent time to add standards and reagents | Standards are added sequentially from low to high concentrations, using multiple guns to pipette | |
Improper use of multiple guns | Calibrate multiple guns, check if the nozzles are tight, and ensure consistent liquid absorption |